{
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "cveMetadata": {
    "cveId": "CVE-2024-43652",
    "assignerOrgId": "00000000-0000-4000-9000-000000000000",
    "requesterUserId": "00000000-0000-4000-9000-000000000000",
    "serial": 1,
    "state": "PUBLISHED"
  },
  "containers": {
    "cna": {
      "providerMetadata": {
        "orgId": "00000000-0000-4000-9000-000000000000"
      },
      "title": "Authenticated command injection in the <redacted> action leads to full remote code execution as root on the charging station",
      "datePublic": "2025-01-09T00:00:00.000Z",
      "problemTypes": [
        {
          "descriptions": [
            {
              "lang": "en",
              "cweId": "CWE-78",
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "lang": "en",
              "cweId": "CWE-250",
              "description": "CWE-250: Execution with Unnecessary Privileges",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "lang": "en",
              "description": "OWASP-A03: Injection"
            }
          ]
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-88",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-88 OS Command Injection"
            }
          ]
        }
      ],
      "affected": [
        {
          "vendor": "Iocharger",
          "product": "Iocharger firmware for AC chargers",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "24120701",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root\nThis issue affects Iocharger firmware for AC model chargers before version 24120701\n\nLikelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.\n\nImpact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete\nfiles and services.",
          "supportingMedia": [
            {
              "type": "text/html",
              "base64": false,
              "value": "Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root<br>This issue affects Iocharger firmware for AC model chargers before version 24120701<br><br>Likelihood: Moderate – The &lt;redacted&gt; binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the &lt;redacted&gt; binary, or convince a user with such access to execute a crafted HTTP request.<br><br>Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete<br>files and services.<br>"
            }
          ]
        }
      ],
      "references": [
        {
          "url": "https://csirt.divd.nl/DIVD-2024-00035/",
          "tags": [
            "third-party-advisory"
          ]
        },
        {
          "url": "https://csirt.divd.nl/CVE-2024-43652/",
          "tags": [
            "third-party-advisory"
          ]
        },
        {
          "url": "https://iocharger.com",
          "tags": [
            "product"
          ]
        }
      ],
      "metrics": [
        {
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ],
          "cvssV4_0": {
            "version": "4.0",
            "attackVector": "NETWORK",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "privilegesRequired": "LOW",
            "userInteraction": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "subConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "HIGH",
            "subIntegrityImpact": "LOW",
            "vulnAvailabilityImpact": "HIGH",
            "subAvailabilityImpact": "HIGH",
            "Safety": "PRESENT",
            "Automatable": "YES",
            "Recovery": "USER",
            "valueDensity": "DIFFUSE",
            "vulnerabilityResponseEffort": "MODERATE",
            "providerUrgency": "NOT_DEFINED",
            "baseSeverity": "CRITICAL",
            "baseScore": 9.3,
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:Y/R:U/V:D/RE:M"
          }
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Wilco van Beijnum",
          "type": "finder"
        },
        {
          "lang": "en",
          "value": "Harm van den Brink (DIVD)",
          "type": "analyst"
        },
        {
          "lang": "en",
          "value": "Frank Breedijk (DIVD)",
          "type": "analyst"
        }
      ],
      "source": {
        "advisory": "DIVD-2024-00035",
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  }
}