{
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "cveMetadata": {
    "cveId": "CVE-2025-36751",
    "assignerOrgId": "00000000-0000-4000-9000-000000000000",
    "requesterUserId": "00000000-0000-4000-9000-000000000000",
    "serial": 1,
    "state": "PUBLISHED"
  },
  "containers": {
    "cna": {
      "providerMetadata": {
        "orgId": "00000000-0000-4000-9000-000000000000"
      },
      "title": "Missing encryption on Local Configuration Interface or Cloud Endpoint Communication - Growatt MIC3300TL-X and ShineLan-X",
      "problemTypes": [
        {
          "descriptions": [
            {
              "lang": "en",
              "cweId": "CWE-311",
              "description": "CWE-311 Missing Encryption of Sensitive Data",
              "type": "CWE"
            }
          ]
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-176",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-176 Configuration/Environment Manipulation"
            }
          ]
        }
      ],
      "affected": [
        {
          "vendor": "Growatt",
          "product": "ShineLan-X",
          "versions": [
            {
              "status": "affected",
              "version": "3.6.0.0",
              "lessThanOrEqual": "3.6.0.2",
              "versionType": "semver"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Encryption is missing on the configuration interface for Growatt ShineLan-X and MIC 3300TL-X. This allows an attacker with access to the network to intercept and potentially manipulate communication requests between the inverter and its cloud endpoint.",
          "supportingMedia": [
            {
              "type": "text/html",
              "base64": false,
              "value": "Encryption is missing on the configuration interface for Growatt ShineLan-X and MIC 3300TL-X. This allows an attacker with access to the network to intercept and potentially manipulate communication requests between the inverter and its cloud endpoint."
            }
          ]
        }
      ],
      "references": [
        {
          "url": "https://csirt.divd.nl/CVE-2025-36751/",
          "tags": [
            "third-party-advisory"
          ]
        }
      ],
      "metrics": [
        {
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ],
          "cvssV4_0": {
            "version": "4.0",
            "attackVector": "ADJACENT",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "privilegesRequired": "NONE",
            "userInteraction": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "vulnAvailabilityImpact": "HIGH",
            "subAvailabilityImpact": "HIGH",
            "Safety": "PRESENT",
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "valueDensity": "NOT_DEFINED",
            "vulnerabilityResponseEffort": "NOT_DEFINED",
            "providerUrgency": "NOT_DEFINED",
            "baseSeverity": "CRITICAL",
            "baseScore": 9.4,
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H"
          }
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Alexandros Tokatlis",
          "type": "finder"
        },
        {
          "lang": "en",
          "value": "Victor Pasman",
          "type": "analyst"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  }
}